There are many kinds of solder joint failure modes in the crystalline Si modules which have been operated in Tsukuba, Japan for 10 years. The modules including mono crystal, multi crystal and hetero junction structure were supplied from four different companies. The samples sliced from the modules are analyzed by using optical microscope, X-ray transmission image, SEM and SEM-EDX. The cross section of module structure beneath the busbar electrode and the finger electrode of the sample is observed by SEM and SEM-EDX. The distribution of Sn, Pb, Ag, Cu, and Si in the cross section region is analyzed by SEM-EDX images. The malfunction positions of the module are specified by blackening in the electrode area in visual inspection as well as identified by EL image inspection. It indicates that there are many types of failure modes such as melting Cu interconnection ribbon, Cu leaching into solder, Ag leaching into solder, long cracks at the interface between solder joint and Ag electrode over 50% of contact region, melting finger line, voids caused by poor wettability of the solder at the interface of Ag electrode, voids caused by excess flux coating, increasing the grain size of solder. It suggests that the crack induces the high electric resistance region and hot spot. Some of cracks may cause the DC arcing which melts Cu ribbon, solder and Si. It was confirmed that soldering process is the most important to enhance the reliability of crystalline Si PV modules.
机译:在日本筑波市运行了10年的晶体硅模块中,有多种焊点失效模式。包括单晶,多晶和异质结结构的模块由四个不同的公司提供。使用光学显微镜,X射线透射图像,SEM和SEM-EDX对从模块切下来的样品进行分析。通过SEM和SEM-EDX观察样品的母线电极和指状电极下方的模块结构的横截面。通过SEM-EDX图像分析了横截面区域中的Sn,Pb,Ag,Cu和Si的分布。通过在目视检查中电极区域变黑来指定模块的故障位置,并通过EL图像检查来识别模块的故障位置。这表明有多种类型的故障模式,例如熔化铜互连带,将铜浸入焊料,将银浸入焊料,在焊点和银电极之间的接触区域(超过接触面积的50%)上出现长裂纹,熔化指状线,空洞等。由于在Ag电极界面处的焊料润湿性差而引起的焊剂,过量的助焊剂涂层导致的空隙会增加焊料的晶粒尺寸。这表明裂纹诱发了高电阻区域和热点。某些裂纹可能会导致直流电弧放电,从而熔化铜带,焊料和硅。已经证实,焊接工艺对于提高晶体硅光伏组件的可靠性最为重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号