The primary focus of this paper is the reliability / failure evaluation of a 26-year-old photovoltaic (PV) monocrystalline silicon (c-Si) system located in Phoenix, Arizona (a hot-dry desert condition). This 4000-frameless-module bipolar system was originally installed in August 1985 with a rated capacity of 175 kW (17° fixed south tilt). This paper presents only the degradation and failure modes, and the degradation rate and its determination of this power plant is presented in another/twin paper of this conference. The results obtained from the extensive visual inspections and other non-intrusive tests made on the entire plant were used to determine the degradation and wear-out failure modes. The encapsualnt browning, cell gridline blossoming, cell-ribbon solder bond degradation, ribbon/metal-strip (copper) attachment degradation/break outside the modules, cell cracks and backsheet delamination have been determined to be the degradation and/or wear-out failure modes of these 26 years old modules in this specific hot-dry desert climate.
机译:本文的主要重点是位于亚利桑那州凤凰城(热干沙漠条件)的具有26年历史的光伏(PV)单晶硅(c-Si)系统的可靠性/故障评估。这种4000帧无模块双极系统最初于1985年8月安装,额定容量为175 kW(向南倾斜17°)。本文仅介绍了退化和故障模式,而该会议的另一篇/两篇论文则介绍了该电厂的退化率及其确定方法。通过对整个工厂进行广泛的目视检查和其他非侵入式测试获得的结果可用于确定退化和磨损失效模式。已确定封装的褐变,电池网格线开花,电池-丝带焊料键退化,带/金属条(铜)附着退化/模块外部破裂,电池裂缝和背板分层是退化和/或磨损失败在这种特定的干热沙漠气候中,这26年的模块的模式。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号