首页> 外文会议>Conseil International des Grands Reseaux Electriques;International Council on Large Electric Systems;CIGRE session >A SURVEY OF THE RELIABILITY OF HVDC SYSTEMS THROUGHOUT THE WORLD DURING 2011 – 2012
【24h】

A SURVEY OF THE RELIABILITY OF HVDC SYSTEMS THROUGHOUT THE WORLD DURING 2011 – 2012

机译:2011年至2012年全球HVDC系统可靠性的调查

获取原文

摘要

CIGRE Advisory Group B4.04 collects data annually on the reliability performance of HVDCsystems in operation throughout the world. This report is a summary of the reliabilityperformance of HVDC systems in operation worldwide during 2011 and 2012. The summary wasdeveloped through data prepared by utilities that operate the HVDC systems and submitted toAdvisory Group B4.04 of CIGRE Study Committee B4 (HVDC and Power ElectronicEquipment). The report contains data on energy availability, energy utilization, forced andscheduled outages and other data in accordance with a reporting protocol developed by theAdvisory Group. The report contains statistics on the frequency and duration of forced outagesfor the years 2011 and 2012 combined with previous data to present a cumulative average offorced outages by frequency and duration covering the years 1988 to 2012. The categories for thecumulative averages are back-to-back stations and two terminal and multi-terminal stations withone and two or more converters per pole.The data in this report, together with that published in previous reports; provide a continuousrecord of reliability performance for the majority of HVDC systems in the world since they firstwent into operation. This now constitutes about 770 system-years of data on thyristor valvesystems.
机译:CIGRE咨询小组B4.04每年收集有关HVDC可靠性性能的数据 系统在全球范围内运作。该报告是可靠性的总结 2011年和2012年在全球范围内运行的HVDC系统的性能。摘要为 通过运行HVDC系统的公用事业公司准备的数据开发并提交给 CIGRE研究委员会B4的B4.04顾问组(高压直流和电力电子 设备)。该报告包含有关能源可用性,能源利用,强制和可再生能源的数据。 计划的停运和其他数据,应根据 咨询小组。该报告包含有关强制中断的频率和持续时间的统计信息 2011年和2012年的数据,再加上以前的数据,得出的累计平均值为 按频率和持续时间(涵盖1988年至2012年)进行的强制中断。 累积平均值是背对背站和两个终端站和多终端站, 每极一个和两个或多个转换器。 本报告中的数据以及先前报告中发布的数据;提供一个连续的 自从世界上大多数HVDC系统首次出现以来的可靠性性能记录 投入运营。现在,这构成了可控硅阀的大约770系统年的数据。 系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号