Substations are integrated in residential, commercial and industrial areas sharing the same buildings and installations. Unexpected failures due to insulation defects appear periodically in substations and can cause large damages, loss of service supply and even blackout. Unfortunately sometimes these failures involve catastrophic fires and emission of toxic gases to the atmosphere.To assure service continuity, electrical insulation diagnosis measurements are needed in substations. Different kinds of measurements (partial discharge - PD -, C, tan, and temperature) permit to determine global or local insulation condition of electrical machines and equipment. This paper is focused on PD measurements in service applied to the three main different types of equipment installed in a substation: power transformers, GIS and bridge insulated cable systems to interconnect the power transformers to the GIS.An integrated solution consisting of a PD measuring system is presented in this paper to get comprehensive PD monitoring of a complete substation. The integrated PD monitoring system for substations has to be able to automatically remove background noise, locate PD sources, discriminate different PD sources located at the same place and identify type of each located PD source. Travelling PD attenuation, phase-resolved PD patterns of different PD sources in different devices and PD sensitivity of different PD sensors used are analyzed in the paper. Special algorithms on the basis of redundant PD data are applied to investigate type and location of different PD sources.The paper also includes real Unión Fenosa Distribución’s experiences of on-line PD measurements using the new PD approach for PD monitoring where internal defects in GIS, cable terminations and power transformers were detected, analyzed and repaired.
机译:变电站集成在住宅,商业和工业区域中,共享相同的建筑物和设施。由于绝缘缺陷而导致的意外故障会在变电站中定期出现,并可能造成较大的损失,服务供应中断甚至停电。不幸的是,有时这些故障涉及灾难性火灾和向大气排放有毒气体。 为了确保服务的连续性,变电站需要进行电气绝缘诊断测量。不同类型的测量(局部放电-PD-,C,tanδ和温度)可以确定电机和设备的整体或局部绝缘状况。本文重点关注应用于变电站中安装的三种主要不同类型设备的在役PD测量:电力变压器,GIS和将电力变压器与GIS互连的桥梁绝缘电缆系统。 本文提出了一种由局部放电测量系统组成的集成解决方案,以对整个变电站进行全面的局部放电监测。用于变电站的集成PD监控系统必须能够自动去除背景噪声,定位PD信号源,区分位于同一位置的不同PD信号源并识别每个定位的PD信号源的类型。本文分析了行进的PD衰减,不同设备中不同PD源的相分辨PD图案以及所使用的不同PD传感器的PD灵敏度。应用基于冗余PD数据的特殊算法来研究不同PD源的类型和位置。 本文还包括真实的UniónFenosaDistribución使用新的PD方法进行PD监测的在线PD测量经验,该方法可检测,分析和修复GIS,电缆终端和电力变压器中的内部缺陷。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号