HYBRID RISER RESISTANCE TO IN-SERVICE FATIGUE LOADING

机译:在役疲劳载荷的混合上升阻力

获取原文

摘要

Riser systems are subjected to complex loading spectra. A wide range of amplitude loading are induced by naturally complex sea states. The complex loading spectrum differs sensibly from the constant amplitude loading commonly adopted for qualification of the product (riser pipe and its girth welds or threaded connections). The present paper reports numerical calculations and a comparison of the actual fatigue loading experienced by different riser systems, Steel Catenary Risers (SCR), Lazy Wave Riser (LWR), Hybrid Risers (HR). For the Hybrid riser system, a good fatigue resistance, due to the vessel and wave first motion decoupling, is obtained. On the other hand, the phenomenon of cross flow vibration induced by Vortex Induced Vibrations (VIV), could significantly affect the hybrid riser fatigue performance. In this case, a sensitivity analysis has been performed to evaluate the influence of different parameters, on the applied fatigue loading, like: riser tension, hydro diameter (i.e. external pipe diameter including coating), riser wall thickness, current velocity. The HR variable amplitude loading spectrum, derived from in-service conditions, referred to Gulf of Mexico scenario, has been calculated and applied in laboratory tests on girth welds of X65, 10.75" OD, 25.4 mm WT riser. Furthermore, the fatigue performance of these tests has been compared to analogous tests on samples subjected to constant and variable amplitude loading available from previous work on SCR system.
机译:立管系统要承受复杂的载荷谱。自然复杂的海况会引起大范围的振幅负载。复杂的载荷谱与通常用于确定产品(立管及其环焊缝或螺纹连接)的恒定振幅载荷明显不同。本文报告了数值计算方法,并比较了不同的立管系统,钢悬链立管(SCR),惰性波浪立管(LWR),混合立管(HR)承受的实际疲劳载荷。对于混合立管系统,由于容器和波浪首先运动解耦,因此获得了良好的抗疲劳性。另一方面,由涡激振动(VIV)引起的横流振动现象可能会显着影响混合立管的疲劳性能。在这种情况下,已经进行了敏感性分析,以评估不同参数对施加的疲劳载荷的影响,例如:立管张力,液压直径(即包括涂层的外管直径),立管壁厚,当前速度。根据在役条件得出的HR可变振幅载荷谱,涉及墨西哥湾的情况,已被计算并应用于X65,外径10.75“,WT 25.4 mm立管的环缝焊缝的实验室测试中。这些测试已与以前在SCR系统上进行的恒定和可变振幅负载样品的类似测试进行了比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号