The Accuracy of Atrial Fibrillation Detection from Wrist Photoplethysmography. A Study on Post-Operative Patients

机译:手腕光学读物术中心房颤动检测的准确性。术后患者的研究

获取原文

摘要

Atrial fibrillation (AF) is the most common type of cardiac arrhythmia. Although not life-threatening itself, AF significantly increases the risk of stroke and myocardial infarction. Current tools available for screening and monitoring of AF are inadequate and an unobtrusive alternative, suitable for long-term use, is needed. This paper evaluates an atrial fibrillation detection algorithm based on wrist photoplethysmographic (PPG) signals. 29 patients recovering from surgery in the post-anesthesia care unit were monitored. 15 patients had sinus rhythm (SR, 67.5 ± 10.7 years old, 7 female) and 14 patients had AF (74.8 ± 8.3 years old, 8 female) during the recordings. Inter-beat intervals (IBI) were estimated from PPG signals. As IBI estimation is highly sensitive to motion or other types of noise, acceleration signals and PPG waveforms were used to automatically detect and discard unreliable IBI. AF was detected from windows of 20 consecutive IBI with 98.45 ± 6.89% sensitivity and 99.13 ± 1.79% specificity for 76.34 ± 19.54% of the time. For the remaining time, no decision was taken due to the lack of reliable IBI. The results show that wrist PPG is suitable for long term monitoring and AF screening. In addition, this technique provides a more comfortable alternative to ECG devices.
机译:心房颤动(AF)是最常见的心脏心律失常类型。虽然没有生命威胁自己,但AF显着增加了中风和心肌梗死的风险。可用于筛选和监控AF的目前的工具是不充分的,并且需要一种不引人注目的替代方案,适合长期使用。本文评估了基于手腕光电读数(PPG)信号的心房颤动检测算法。监测29例从手术中恢复的患者进行监测。 15名患者有窦性心律(SR,67.5±107岁,7名女性)和14名患者在录音期间有AF(74.8±8.3岁)。从PPG信号估计间隔间隔(IBI)。由于IBI估计对运动或其他类型的噪声非常敏感,因此使用加速信号和PPG波形自动检测和丢弃不可靠的IBI。从20个连续IBI的窗口检测到AF,灵敏度为98.45±6.89%,76.34±19.54%的特异性为99.13±1.79%。对于剩下的时间,由于缺乏可靠的IBI,没有采取任何决定。结果表明,手腕PPG适用于长期监测和AF筛选。此外,该技术为ECG设备提供了更舒适的替代方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号