首页> 外文会议>Annual IEEE Applied Power Electronics Conference and Exposition >A single mode load tracking voltage mode controller with near minimum deviation transient response
【24h】

A single mode load tracking voltage mode controller with near minimum deviation transient response

机译:具有近最小偏差瞬态响应的单模负载跟踪电压模式控制器

获取原文

摘要

This paper introduces a practical single-mode quasi constant-frequency controller that provides practically minimum output voltage deviation during load transients. This control scheme eliminates the need for two separate controllers for steady-state and transient operation and the associated potential mode transition problems which are characteristic of numerous fast response solutions. The controller only relies on the detection of changes in the output capacitor current polarity and a simple PI compensator to provide fast transient response and tight voltage regulation. The effectiveness of this mixed-signal controller is demonstrated with a 600 kHz, 15 W single-phase buck converter based experimental prototype. During load transients, the inductor current is shown to be corrected within one switching cycle with near-minimum output voltage deviation.
机译:本文介绍了一种实用的单模准恒定频率控制器,在负载瞬变期间提供实际最小输出电压偏差。该控制方案消除了对稳态和瞬态操作的两个单独控制器的需求以及具有许多快速响应解决方案的特征的相关电位模式转换问题。控制器仅依赖于检测输出电容器电流极性和简单PI补偿器的变化,以提供快速的瞬态响应和紧密的电压调节。通过基于600 kHz,15W单相降压转换器的实验原型来对该混合信号控制器的有效性进行说明。在负载瞬变期间,示出电感电流在一个开关周期内校正,其具有近最小的输出电压偏差。