This paper presents the design of a FPGA-based digital counter for the measurement of the oscillation frequency of Quartz Crystal Microbalance (QCM) sensors. This work is part of a bigger project focused on the development of a standalone QCM system for the analysis and characterization of organic coatings. The method used to implement the digital counter is the direct frequency measurement. Therefore, special attention is paid in the design of the time-base generator. Measurement errors due to the drift of the system oscillator are discussed, and several solutions are proposed taking advantage of the embedded DLL circuits available in the FPGAs. The designed digital counter is implemented and tested using the Xilinx’s Spartan XC3S200 FPGA.
机译:本文介绍了基于FPGA的数字计数器,用于测量石英晶体微稳态(QCM)传感器的振荡频率。这项工作是一个更大项目的一部分,专注于开发独立QCM系统,用于有机涂料的分析和表征。用于实现数字计数器的方法是直接频率测量。因此,在时间基发生器的设计中支付了特别的注意。讨论了由于系统振荡器的漂移引起的测量误差,提出了几种解决方案,利用了FPGA中可用的嵌入式DLL电路。使用Xilinx的Spartan XC3S200 FPGA来实现和测试设计的数字计数器。