This paper introduces an adequate loss model, based on the experimental results, which can be used to estimate the losses in hard-switched and soft-switched inverters. As an example and considering the use of IGBTs, it compares the losses produced by hard-switched, Auxiliary Resonant Commutated Pole (ARCP) and Quasi-Square-Wave (QSW) inverters for different current and frequencies. The study takes into account conduction losses, switching losses (turn-on and turn-off losses) and losses in the passive components. In the proposed model, the device power losses are considered as a function of the circuit and operating parameters. Experimental results validate the loss model employed.
机译:本文介绍了一种适当的损耗模型,基于实验结果,可用于估计硬开关和软切换逆变器中的损耗。作为示例并考虑使用IGBTS,它比较了硬开关,辅助谐振换向极(ACCP)和用于不同电流和频率的准方波(QSW)逆变器产生的损耗。该研究考虑了导通损耗,切换损耗(开启和关闭损耗)和被动组件中的损耗。在所提出的模型中,设备功率损耗被认为是电路和操作参数的函数。实验结果验证了所采用的损失模型。