A multi-element silicon photomultiplier (SiPM) based time-of-flight (ToF) block detector module for Positron Emission Tomography (PET) has been developed. The detector module is based on a 4 × 4 array of LYSO-SiPM elements (Hamamatsu MPPC S10931-050P), with individual bias supply and read out by individual wideband RF amplifier to maximize timing performance. Each output is digitized with a channel of the high speed CAEN V1742 (32 channels, 5 GHz sampling, 12-bit amplitude resolution) to acquire the raw waveform and extract relevant information. As the digitizer is unable to trigger on itself, a trigger board to output a fast pulse that triggers the digitizer whenever any pixel of the detector detects a signal, and process coincident events, has also been fabricated. To assess the performance of one of the modules, a 4 × 4 LYSO scintillator array (3 × 3 × 5 mm3 elements) was coupled to the SiPM photodetectors and energy resolution and timing resolution measurements were performed using a Ge-68 source. At 1.4 V overvoltage, the energy resolution, not corrected for saturation effects of the SiPM, varied from a minimum of 10.1 % to a maximum of 13.3 % with an average energy resolution of 11.4 ± 0.8 % across the 16 channels. With a reference detector (single 3 × 3 × 5 mm3 LYSO and Hamamatsu S10362-33), the average coincidence resolving time (CRT) across the detector module (16 pixels) was 211 ± 6 ps FWHM at 2.2 V overvoltage.
机译:已经开发出用于正电子发射断层扫描(PET)的基于多元素硅光电倍增管(SIPM)飞行时间(TOF)块检测器模块。探测器模块基于4× 4阵列Lyso-SiPM元件(Hamamatsu MPPC S10931-050P),各个偏置电源,由各个宽带RF放大器读出,以最大化定时性能。每个输出都以高速CAEN V1742(32个通道,5 GHz采样,12位幅度分辨率)的信道数字化,以获取原始波形并提取相关信息。由于数字转换器本身无法触发,因此每当检测器的任何像素检测到信号时,触发器将输出快速脉冲,并在检测到信号的任何像素和处理重合事件时,还被制造。评估其中一个模块,4&#x00d7的性能; 4 Lyso闪烁体阵列(3× 3× 5 mm 3 元素)耦合到SIPM光电探测器,并且使用GE-68源进行能量分辨率和定时分辨率测量。在1.4 V过电压下,能量分辨率,未校正SIPM的饱和效应,从最低10.1%到最多10.1%,最大为11.4&#x00b1的平均能量分辨率为13.3%;在16个通道上0.8%。使用参考检测器(单3× 3× 5 mm 3 lyso和hamamatsu s10362-33),横跨探测器模块的平均重合时间(CRT)(16像素)是211± 6 PS FWHM在2.2 V过压。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号