首页> 外文会议>International Conference on Electrical Machines and Systems >Cooling system design and thermal analysis of dual mechanical port machine considering thermal contacts
【24h】

Cooling system design and thermal analysis of dual mechanical port machine considering thermal contacts

机译:考虑热触点的双机械端口机的冷却系统设计与热分析

获取原文

摘要

For smaller and more reliable dual mechanical port (DMP) machine in wind power generation system, there is a need for thermal analysis in the design stage. In this paper, the thermal analysis considering thermal contacts and the cooling system design for a DMP prototype machine are investigated. Some basic knowledge of the heat transfer used in electrical machines and the flow distribution in cooling ducts of the forced-air cooling system are introduced. Considering two typical thermal contacts, finite-element analysis (FEA) of the thermal field is investigated to obtain the detailed temperature distribution. Then, initial design of the cooling system commonly used in electrical machines is tested in the thermal analysis. Finally, a 20 kW DMP prototype machine with the improved wholly forced-air cooling system which can survive with 160% rated load is designed.
机译:对于风力发电系统中的较小且更可靠的双机械端口(DMP)机器,需要在设计阶段进行热分析。本文研究了考虑热触点和DMP原型机的热触点和冷却系统设计的热分析。引入了电机中使用的传热和传热的一些基本知识和强制空气冷却系统的冷却管道中的流动分布。考虑到两个典型的热触点,研究了热场的有限元分析(FEA)以获得详细的温度分布。然后,在热分析中测试电机中常用的冷却系统的初始设计。最后,设计了一个20千瓦DMP原型机,具有改进的完全强制空气冷却系统,可以使用160%额定负载存活。