Using wavelet to achieve fault line selection, traditional methods are all in accordance with the principles of the largest energy to determine the characteristic band. However, this square sum operation overlooks; the detailed band features, so when the fault characteristics are not obvious, it will cause wrong judgment. For transient quantity mutations are the basis of wavelet fault line selection, a new perspective that "the frequency band with the maximum absolute value of adjacent wavelet packet decomposition coefficients difference" should be chosen as the line selection frequency band is first proposed in this paper after the wavelet packet decomposition of the complex transient mutational quantity. The paper expounds on the detailed fault line selection steps and practical criterion, and also analyzes the selection of mother wavelet, sampling frequency and scale of the decomposition. Theoretical analysis and simulation results show that the method can accurately select fault line, with high reliability.
机译:使用小波实现故障线选择,传统方法都是根据最大能量的原理来确定特征频带。但是,这种方形的概括俯瞰;详细频段功能,因此当故障特性不明显时,会导致错误的判断。对于瞬态量突变是小波故障线选择的基础,应该选择“具有相邻小波分组分解系数差的频带的频带的频带”作为线选择频带之后首先选择的新视角小波包分解复杂的瞬态突变数量。本文阐述了详细的故障线选择步骤和实际标准,并分析了母小波的选择,采样频率和分解的比例。理论分析和仿真结果表明,该方法可以精确选择断层线,具有高可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号