Monitoring the health of large synchronous Machines is now an integral part of their operation. The stator inter-turn short circuit fault is one of the serious fault and have a deep influence on the safety and effectiveness of the machine. This paper describes an online monitoring method with no sensor required to predict these two faults of synchronous condenser before they propagate to a level that can leading to catastrophic failure. The paper develops an analytical model for the online fault predicting by only knowing the stator and field current, and the detailed 2D FEA models will also be built to take the core saturation and leakage magnetic field into consideration. Finally, the method will be validated by experimental results.
机译:监控大型同步机的健康现在是他们操作的一个组成部分。定子匝间短路故障是严重故障之一,对机器的安全性和有效性具有深入影响。本文介绍了一种在线监测方法,没有传感器需要在传播到可能导致灾难性故障的水平之前预测同步冷凝器的这两个故障。本文仅通过了解定子和现场电流来开发用于在线故障的分析模型,并且还将考虑核心饱和度和泄漏磁场的详细的2D FEA模型。最后,该方法将通过实验结果验证。