首页> 外文会议>International Conference on Electrical Machines and Systems >Experimental verification of dead-time compensation scheme for pulse width modulation scheme on six-switch two three-phase output inverter
【24h】

Experimental verification of dead-time compensation scheme for pulse width modulation scheme on six-switch two three-phase output inverter

机译:六开关二三相输出逆变器脉宽调制方案的死区补偿方案的实验验证

获取原文
获取外文期刊封面目录资料

摘要

Six-switch two three-phase output inverter can be controlled by pulse width modulation (PWM) scheme. Each switching device used in voltage source inverter requires dead-time. The output waveform of the inverter is distorted when the dead-time is inserted. Therefore, the output current THD (total harmonics distortion) increases. Applying a dead-time compensation scheme, the distortion caused by the dead-time can be reduced. This paper shows the effectiveness of a dead-time compensation scheme which is applied to a PWM scheme for six-switch two three-phase output inverter by experiment.
机译:六开关两个三相输出逆变器可以通过脉宽调制(PWM)方案进行控制。电压源逆变器中使用的每个开关设备都需要停滞时间。插入空载时间后,逆变器的输出波形会失真。因此,输出电流THD(总谐波失真)增加。应用空载时间补偿方案,可以减少由空载时间引起的失真。本文通过实验证明了将死区补偿方案应用于六开关二三相输出逆变器的PWM方案的有效性。