首页> 外文会议>International Conference on Electrical Machines and Systems >Leakage current reduction for transformerless three-level T-Type photovoltaic grid-connected inverter
【24h】

Leakage current reduction for transformerless three-level T-Type photovoltaic grid-connected inverter

机译:无变压器三电平T型光伏并网逆变器的漏电流降低

获取原文

摘要

This paper proposed the common mode model of three-level T-Type inverter. Then a kind of improved LCL filter, where the capacitor common point was linked to the DC neutral point, was used to eliminate the leakage current. However, this improved LCL filter changes the mechanism of the neutral-point potential. Traditional algorithms, such as the distribution factor algorithm, are no longer applicable. In order to control the neutral-point potential, a new general distribution factor algorithm was proposed in this paper. Experimental results demonstrate the availability and correctness of the theoretical analysis and algorithm.
机译:提出了三电平T型逆变器的共模模型。然后使用一种改进的LCL滤波器,其中电容器的公共点与DC中性点相连,以消除泄漏电流。但是,这种改进的LCL滤波器改变了中性点电位的机制。诸如分配因子算法之类的传统算法不再适用。为了控制中性点电位,提出了一种新的通用分布因子算法。实验结果证明了理论分析和算法的有效性和正确性。