首页> 外文会议>International Scientific Conference on Electric Power Engineering >Improving the Operating Parameters of the 300 kV AC Test System
【24h】

Improving the Operating Parameters of the 300 kV AC Test System

机译:提高300 kV AC测试系统的操作参数

获取原文

摘要

The High Voltage Test Laboratory in CVVOZEPowerLab is equipped with a Haefely Hipotronics HV Test Transformer HHT7300-300T5-760. This test system is used for withstand voltage, breakdown voltage tests and diagnostics of dielectrics - measurement of partial discharges and electronic bridge measurement up to 300 kV. Unfortunately, the system produces output voltage with high value of harmonic distortion, mainly in the condition of low output load. Higher harmonics in the output test voltage make it impossible to carry out accurate withstand tests and affects the measurement accuracy of the dissipation factor and the operation of the PD system. These problems were solved for last 5 years and currently are found several partial solutions. In this paper are described several basic concepts used to improve the operating parameters of the 300 kV AC source.
机译:CVVozpowerlab中的高压测试实验室配备了HHT7300-300T5-760的Hafice Hipotronics HV测试变压器。该测试系统用于耐压,击穿电压测试和介质的诊断 - 部分放电测量和高达300kV的电子桥梁测量。不幸的是,该系统产生高谐波失真值的输出电压,主要在输出负载的条件下。输出测试电压的更高谐波使得无法进行准确的耐用测试,并影响耗散因子的测量精度和PD系统的操作。过去5年来解决了这些问题,目前发现了几种部分解决方案。本文描述了几种用于改善300 kV AC源的操作参数的基本概念。