The water-cooling wall tube explosion of rear flue for ultra-supercritical boiler has been studied in this work. The macrograph analysis, chemical analysis, mechanical tests, and metallurgical microscopic structure analysis have been conducted to investigate the wall tube failures and their causes. The results show that the failure of water-cooling wall tubes was due to resonant vibration. A series relevant counter measures to prevent the failure has been put forward in this work.
机译:在这项工作中研究了超超临界锅炉后烟管的水冷却壁管爆炸。已经进行了宏观分析,化学分析,机械测试和冶金微观结构分析,以研究壁管故障及其原因。结果表明,水冷壁管的失效是由于谐振振动。在这项工作中提出了一个有关措施,以防止失败的措施。