首页> 外文期刊>International Journal of Heat and Mass Transfer >Numerical analysis on the flow instability of parallel channels in water wall of an ultra-supercritical CFB boiler
【24h】

Numerical analysis on the flow instability of parallel channels in water wall of an ultra-supercritical CFB boiler

机译:超超临界循环流化床锅炉水冷壁内平行通道流动不稳定性的数值分析

获取原文
获取原文并翻译 | 示例
           

摘要

A general calculation model based on the time-domain method is established for analyzing flow instability in parallel channels. In this model, the governing equations of mass, momentum, and energy are dis-cretized and solved using the first-order upwind scheme. A numerical computational program called Dynsys is developed in Fortran language to analyze the flow instability occurring in the water wall of an ultra-supercritical CFB boiler with annular furnace. Comparing the calculation results of Dynsys with the experimental results shows that the model is reasonable and accurate for practical engineering application. On the basis of the validated model, the typical parallel channels in water wall of ultra-supercritical CFB boiler are simulated. Results show that, under the condition of invariable inlet pressure, temperature, and total mass flow rate, as well as 1.2 times heat flux disturbance applied on the parallel channels of ultra-supercritical CFB boiler, the fluctuation of inlet flow rate versus time in two channels is out of phase. In addition, the amplitude of flow pulsation decreases with time first and then returns to the steady state. Therefore, the flow in the parallel channels of ultra-supercritical CFB boiler with annular furnace is stable. Compared with the flow instability in single channel, the calculating results show that the flow in parallel channels was more stable within the range of parameters in the present paper.
机译:建立了基于时域方法的通用计算模型,以分析并行通道中的流动不稳定性。在该模型中,质量,动量和能量的控制方程式被离散化,并使用一阶迎风方案求解。用Fortran语言开发了一个名为Dynsys的数值计算程序,以分析超高临界CFB锅炉(带环形炉)的水冷壁中的流动不稳定性。将Dynsys的计算结果与实验结果进行比较表明,该模型对于实际工程应用是合理,准确的。在验证模型的基础上,模拟了超超临界循环流化床锅炉水冷壁的典型平行通道。结果表明,在入口压力,温度,总质量流量不变的条件下,在超超临界循环流化床锅炉并联通道上施加1.2倍的热通量扰动,入口流量随时间的波动是两个渠道异相。另外,流动脉动的幅度首先随时间减小,然后返回稳定状态。因此,具有环形炉的超超临界循环流化床锅炉在平行通道中的流动是稳定的。与单通道流动不稳定性相比,计算结果表明,在参数范围内,平行通道的流动更为稳定。

著录项

  • 来源
  • 作者单位

    State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, No. 28 Xianning West Road, Xi'an 710049, Shaanxi, China;

    State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, No. 28 Xianning West Road, Xi'an 710049, Shaanxi, China;

    State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, No. 28 Xianning West Road, Xi'an 710049, Shaanxi, China;

    State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, No. 28 Xianning West Road, Xi'an 710049, Shaanxi, China;

    State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, No. 28 Xianning West Road, Xi'an 710049, Shaanxi, China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    ultra-supercritical cfb boiler; parallel channel; flow instability; numerical analysis;

    机译:超超临界循环流化床锅炉;并行通道流量不稳定;数值分析;