摘要

It is well known that interactions between weakly damped LC input filters and constant power loads (CPL) can lead to instability. This paper deals, in particular, with this problem when several CPL are connected to the network through undamped LC filters. The second goal is the energy management. They are mainly achieved by controlling the energy flow between the network and a storage device. The latter is a super-capacitor connected to the network via two DC-DC converters. After Port controlled Hamiltonian (PCH) expression of the system dynamics, they are controlled using the passivity approach. A proof of stability of the controlled system is given. Robustness tests relative to parameters uncertainties are realized and simulation results confirm the validity the proposed approach. This approach has also the advantage of requiring the measurement of only two state variables.
机译:众所周知,弱阻尼LC输入滤波器与恒定功率负载(CPL)之间的相互作用会导致不稳定。当几个CPL通过无阻尼LC滤波器连接到网络时,本文特别解决了这个问题。第二个目标是能源管理。它们主要是通过控制网络与存储设备之间的能量流来实现的。后者是通过两个DC-DC转换器连接到网络的超级电容器。在端口控制的系统动力学哈密顿量(PCH)表达之后,使用无源方法对其进行控制。给出了受控系统稳定性的证明。相对于参数不确定性的鲁棒性测试得以实现,仿真结果证实了该方法的有效性。该方法还具有仅需要测量两个状态变量的优点。