When commutator profile distortion in DC motors or collector ring profile distortion in AC generators or motors are caused, stabilities and reliabilities of sliding contact phenomena will be lost, causing mechanical contact instabilities and contact voltage instabilities. In this paper, how to estimate the mechanical vibration out of the ring profile distortion and how to estimate contact voltage deviation out of the mechanical vibration, are introduced.
机译:当DC电动机或收集器环形轮廓失真引起交流发电机或电机中的换向器轮廓失真时,滑动接触现象的稳定性和可靠性将会丢失,导致机械接触不稳定性和接触电压不稳定性。在本文中,介绍了如何估计环形轮廓失真的机械振动以及如何估计机械振动的接触电压偏差。