Fully automated assessment of left ventricular volumes, function and mass from cardiac MRI

机译:全自动评估左心室体积,功能和来自心脏MRI的质量

获取原文

摘要

The importance of quantification of left ventricular (LV) size, function and mass is increasingly recognized through growing evidence about the prognostic value of these indices and their diagnostic role in patient follow-up during therapy. However, quantitative evaluation from cardiac magnetic resonance (CMR) images relies on manual tracing of LV endo- and epicardial boundaries, which is subjective and time-consuming. Our goal was to develop a fully automated technique for the detection of these boundaries to assess LV volumes, ejection fraction (EF) and mass. Our automated approach consists of: 1) identification of the LV cavity based on detection of moving and circular structures in short-axis views; 2) endocardial detection using a region-based probabilistic level set model to allow volume measurements throughout the cardiac cycle; 3) epicardium detection at end-diastole based on an edge-based level set model to allow LV mass measurement. This approach was tested in 10 patients by comparing automatically derived LV volumes, EF and mass using manual tracing as a reference. Automated detection of the endo- and epicardial boundaries took <;5 minutes per patient on a standard PC. The detected boundaries were in good agreement with manual tracing. As a result, LV volumes, EF and mass showed good inter-technique concordance, reflected by minimal biases and narrow limits of agreement. The proposed technique allows fully automated, fast and accurate measurements of LV volumes, EF and mass from CMR images, which may address the growing clinical need for quantitative assessment.
机译:通过越来越多的证据越来越多地认识到左心室(LV)尺寸,功能和质量的重要性,通过越来越多的证据以及治疗期间患者随访中的诊断作用以及患者的诊断作用。然而,来自心脏磁共振(CMR)图像的定量评估依赖于LV内皮和心外膜边界的手动跟踪,这是主观和耗时的。我们的目标是开发一种全自动技术,用于检测这些界限,以评估LV体积,喷射分数(EF)和质量。我们的自动化方法包括:1)基于在短轴视图中检测移动和圆形结构的检测来识别LV腔; 2)使用基于区域的概率水平设定模型的心内膜检测来允许整个心循环的体积测量; 3)基于基于边缘的水平设定模型的端部舒张外膜检测,以允许LV质量测量。通过使用手动跟踪作为参考,通过比较自动导出的LV体积,EF和质量来在10名患者中进行这种方法。在标准PC上每位患者自动检测endo-和心外膜边界的检测。检测到的边界与手动跟踪有关。结果,LV体积,EF和质量显示出良好的技术间协调,反映在最小的偏差和狭窄的协议限制。该提出的技术允许从CMR图像完全自动化,快速和精确测量的LV体积,EF和质量,这可能解决了越来越多的临床需求对定量评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号