This paper evaluates the fault detection performance of stator winding turn-to-turn short in the inverter-fed permanent magnet (PM) machines based on the high frequency (HF) voltage signal injection. On the basis, a HF pulsating-type AC voltage is injected on the direction of d-axis with respect to the rotor-referred synchronous frame. Once turn short occurs, a fault reflected current signal results due to the change of inductance on the faulty phase. Comparing to prior turn fault detection techniques using synchronized voltage or current signals for the torque production, this HF fault reflected current signal is immune to the speed variation. In addition, the torque load only affects the inductance saturation but not the change of phase and magnitude. It leads to a reduced impact on the load to the HF fault reflected current. It is possible to monitor a minor turn fault (2~3% turn short per phase) at different operating conditions. A salient PM machine with designed turn-to-turn short is built to verify the proposed fault diagnostic method.
机译:本文基于高频(HF)电压信号注入,评估定子绕组转向转动逆转器短路的故障检测性能。在基础上,HF脉动型AC电压相对于转子参考的同步框架在D轴的方向上注入。发生短路后,由于故障阶段的电感而变化,故障反射电流信号导致。与先前的转弯故障检测技术相比,使用同步电压或电流信号进行扭矩产生,该HF故障反射电流信号对速度变化免疫。此外,扭矩负载仅影响电感饱和度,而不是相位和幅度的变化。它导致对HF故障反射电流的负荷的影响降低。在不同的操作条件下,可以监控轻微的转闭(每相2〜3%的转弯)。构建了具有设计转弯短路的PM机器,以验证所提出的故障诊断方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号