Loop formation may occur in cables, ropes, and also risers -flexible pipes or umbilical cables - used for offshore exploitation. The phenomenon occurs when there is enough torsion moment in the line and also a low tension condition or, even in the cases of cable slack (almost zero tension) with some torsion moment. Many references discuss about the loop formation prediction in different conditions, but mostly for the cases of an initial straight cable (rope or riser) which is usually represented by a beam. The problem of the loop formation in a catenary riser including the nonlinear contact with the seabed is very important, once during the riser installation in some conditions a low tension combined with torsion moment can lead to the loop formation, which is undesirable. There is a necessity of a better understanding of this theme. The present work explores the loop formation in catenary risers comparing the results of the static and the dynamic predictions, showing an asymptotic tendency from the dynamics to the statics. For that study, geometrically-exact nonlinear beam models were employed in the statics and in dynamics, leading to very realistic loop formation predictions.
机译:在用于海上开采的电缆,绳索以及立管(挠性管或脐带缆)中可能会形成回路。当线路中有足够的扭力力矩并且还处于低张力状态时,甚至在电缆具有松弛力矩(松弛的情况下,张力几乎为零)的情况下,都会出现这种现象。许多参考文献都讨论了在不同条件下的回路形成预测,但是大多数情况下是针对通常由光束表示的初始直电缆(绳或立管)的情况。在悬链式立管中包括与海床的非线性接触的环形成问题非常重要,一旦在某些条件下在立管安装过程中,低张力和扭转力矩会导致形成环,这是不希望的。有必要更好地理解这个主题。本工作探讨了悬链立管中的回路形成,比较了静态和动态预测的结果,显示了从动态到静态的渐近趋势。对于该研究,在静力学和动力学中采用了几何精确的非线性梁模型,从而得出非常现实的回路形成预测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号