This paper describes a fuse model that can calculate the fuse current and voltage fluctuations from the start of a shorting accident to the completion of the fuse blowing. In the previous paper, the melting time and fuse current were calculated by considering the detector's current and diffusion factor during the melting period. Here, we extend the model to calculate the arcing time. Our model has a capacitor model that can represent the level of voltage fluctuation and waveforms of decreasing current. It also has an arc switch that can represent the voltage drop when the fuse becomes completely isolated from the circuit. Simulation results are in good agreement with the experimental results. We can calculate these characteristics easily, automatically, and accurately. Once we have obtained the fuse blowing parameters by performing only one experiment, we can calculate these characteristics even if the system is changed.
机译:本文介绍了一种熔断器模型,可以从短路事故开始到熔断器吹扫的开始时计算熔丝电流和电压波动。在前一篇文章中,通过考虑熔化时段期间的检测器的电流和扩散因子来计算熔化时间和熔丝电流。在这里,我们扩展模型以计算电弧时间。我们的模型具有电容器模型,可以表示电压波动水平和降低电流的波形。它还具有电弧开关,当熔断器完全从电路完全隔离时,可以表示电压降。仿真结果与实验结果吻合良好。我们可以轻松,自动,准确地计算这些特征。一旦我们通过仅执行一个实验就获得了熔丝吹扫参数,即使系统改变,我们也可以计算这些特征。