The municipality of Gnesta, Sweden will in the future offer triple-play internet broadband services to its inhabitants. In the past the IT Service Department of Gnesta used small AC UPS of different ages to cope with the need for uninterruptible power backup at the data centre to match the reliability of telecommunications. Battery maintenance became a burden and they also found that this solution gave little or negligible back-up time. The IT-management of the Gnesta Municipality decided to try the HVDC UPS concept which seemed to promise superior transient protection, energy savings, reliability, power quality and economy. This paper describes one year of trial and full operation of a 350 V DC uninterruptible power system, which may very well be the world's first in critical operation. The paper also describes the HVDC UPS system, designed by Netpower Labs AB and used at the Gnesta municipality. As the first commercial system it meets the ETSI standard EN 300 132-3. Since there currently are very few types of servers and data equipment specifically designed for direct operation from HVDC (350 V DC) Netpower has explored the possibility to use standard equipment and run them on HVDC as an intermediate step. Netpower has performed a study on various existing power supplies for data servers and other computer equipment to check their compatibility with the HVDC concept. The energy savings potential of 30% made possible by HVDC UPS (compared to present AC UPS) is discussed in the paper. The conclusion is that a HVDC UPS 350 V gives superior transient protection, great energy savings and has potential for future enhanced data centre energy savings as well as it offers very high reliability and good economy.
机译:瑞典的GNESTA市将来将在未来为其居民提供三重互联网宽带服务。在过去的IT服务部Gnesta使用小型AC UPS的不同年龄段来应对数据中心的不间断电源备份,以匹配电信的可靠性。电池维护成了负担,他们还发现,此解决方案很少或忽略不计的备用时间。 GNESTA市的IT管理决定尝试HVDC UPS概念,似乎承诺卓越的瞬态保护,节能,可靠性,电能质量和经济。本文介绍了一年的试验和全运行350 V直流不间断电力系统,这可能是世界上首先在关键操作中的第一个。本文还介绍了由Netpower Labs AB设计的HVDC UPS系统,并在GNESTA Municipality中使用。作为第一个商业系统,它符合ETSI标准EN 300 132-3。由于目前有极少数类型的服务器和数据设备专门用于直接操作从HVDC设计的(350 V DC)Netpower已经探索使用标准设备和运行它们上HVDC作为中间步骤的可能性。 NetPower已经对数据服务器和其他计算机设备进行了各种现有电源的研究,以检查其与HVDC概念的兼容性。本文讨论了HVDC UPS(与目前AC UPS相比)可以实现30%的节能潜力。结论是,HVDC UPS 350 V提供了卓越的瞬态保护,节能,具有未来增强数据中心能源节省的潜力,以及它提供了非常高的可靠性和经济性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号