Effect of Unresponsive Time for User's Touch Action of Selecting an Icon on the Video Mirror Interface

机译:在视频镜接口上选择图标的用户触摸动作的效果

获取原文

摘要

Contactless input methods implementing body motion allow users to control computer systems easily and enjoyably. We focus on the "video mirror interface" as an example of these methods. A user of the video mirror interface can operate the computer system by selecting virtual objects on a screen with his/her hand. However, if a selection operation is completed as soon as the user touches the virtual object, erroneous selections will frequently occur. Therefore, it is necessary to insert a certain period of unresponsiveness after a user's touch action to prevent selection error. We evaluate effects of the unresponsive time when selecting a virtual object in a video mirror interface. The result of an experimental evaluation indicates that an acceptable range for the unresponsive time is 0.3 to 0.5 s.
机译:非接触式输入方法实现身体运动允许用户轻松且易于控制计算机系统。我们专注于“视频镜面界面”作为这些方法的示例。视频镜接口的用户可以通过用他/她的手选择屏幕上的虚拟对象来操作计算机系统。但是,如果在用户触摸虚拟对象后立即完成选择操作,则会经常发生错误的选择。因此,必须在用户的触摸动作之后插入一定时间的非反应性以防止选择错误。在视频镜像界面中选择虚拟对象时,我们会评估无响应时间的效果。实验评价的结果表明,无反应时间的可接受范围为0.3至0.5秒。