首页> 外文会议>International high-level radioactive waste management conference >DRY CASK STORAGE SYSTEMS THERMAL ANALYSIS PROJECT
【24h】

DRY CASK STORAGE SYSTEMS THERMAL ANALYSIS PROJECT

机译:干桶储存系统热分析项目

获取原文

摘要

As part of the development of technical bases which support the extended storage and transportation of used nuclear fuel, Pacific Northwest National Laboratory (PNNL) has implemented detailed thermal analysis methods for the calculation of best estimate temperatures of Dry Cask Storage (DCS) systems. These methods were used to model a NAC International MAGNASTOR~? cask located at the Catawba Nuclear Station (Catawba) which is operated by Duke Energy This cask has one of the highest total heat loads of any DCS system loaded in the U.S.. Using best estimate operational data from the utility, fuel assembly and cask design information from the vendors, and decay heat estimates from Oak Ridge National Laboratory (ORNL), PNNL calculated the maximum cladding temperature of 307°C. This is well below the 400°C regulatory guidance limit.
机译:作为支持使用核燃料延长储存和运输的技术基础的一部分,太平洋西北国家实验室(PNNL)已经实施了用于计算干桶储存(DCS)系统最佳估计温度的详细的热分析方法。这些方法用于模拟NAC国际胶卷〜?位于Catawba核电站(Catawba)的桶,该卡瓦斯能源运营该木桶拥有美国任何DCS系统的最高总热量负荷之一。使用来自公用事业,燃料组件和桶设计信息的最佳估算运营数据来自供应商,橡木岭国家实验室(ORN1)的衰变热估计,PNNL计算最大的307°C的层状温度。这远低于400°C的监管指导限额。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有