A detailed three-dimensional thermal and fluid analysis of a vertical dry storage cask with a canister containing 32 high-burnup pressurized water reactor (PWR) spent fuel assemblies for a storage of 50 years was carried out using a CFD simulation. The input decay heat value was calculated based on a Westinghouse 17 x 17 PWR fuel assembly using the well validated package ORIGAMI imbedded in SCALE, with a total heat load of 38.44 kW for year 5 and 10.67 kW for year 55. The temperature dependent and anisotropic thermal properties of the fuel assemblies, filling gas within the canister, and air covering the canister were considered in order to preserve accuracy. A peak temperature of 621.4 K occurred in the upper part of the fuel assemblies for at year 5, deceasing to 423.0 K after 50-year service. The simulation results shed light on the temperature and flow environment within the canister for an operational time of 50 years. Published by Elsevier Ltd.
机译:使用CFD模拟,对带有32个高燃压水反应堆(PWR)乏燃料组件的碳罐的垂直干燥储罐进行了详细的三维热和流体分析,可存储50年。输入的衰减热值是根据Westinghouse 17 x 17 PWR燃料组件,使用嵌入SCALE的经过验证的软件包ORIGAMI计算得出的,第5年的总热负荷为38.44 kW,第55年的总热负荷为10.67 kW。取决于温度和各向异性为了保持精度,考虑了燃料组件的热特性,罐内的填充气体以及覆盖罐的空气。在第5年,燃料组件的上部出现峰值温度621.4 K,在使用50年后降低到423.0K。模拟结果揭示了罐中50年的运行时间中的温度和流动环境。由Elsevier Ltd.发布

著录项

  • 来源
    《Annals of nuclear energy》 |2018年第2期|132-142|共11页
  • 作者单位

    Virginia Polytech Inst & State Univ, Dept Mech Engn, 635 Prices Fork Rd, Blacksburg, VA 24061 USA;

    Virginia Polytech Inst & State Univ, Dept Mech Engn, 635 Prices Fork Rd, Blacksburg, VA 24061 USA;

    Virginia Polytech Inst & State Univ, Dept Mech Engn, 635 Prices Fork Rd, Blacksburg, VA 24061 USA;

    Virginia Polytech Inst & State Univ, Dept Mech Engn, 635 Prices Fork Rd, Blacksburg, VA 24061 USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    CFD; Dry cask storage; Nuclear; Thermoelectric;

    机译:差价合约(CFD);干桶存储;核;热电;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号