首页> 外文会议>European Conference on Power Electronics and Applications >Detection of inter-turns short circuits in permanent magnet synchronous motors operating under transient conditions by means of the zero sequence voltage
【24h】

Detection of inter-turns short circuits in permanent magnet synchronous motors operating under transient conditions by means of the zero sequence voltage

机译:通过零序电压检测在瞬态条件下操作的永磁同步电动机中的转弯短路。

获取原文

摘要

This work proposes the zero sequence voltage component (ZSVC) of the stator three-phase voltages as a method for detecting winding inter-turns short circuits in permanent magnet synchronous motors PMSM operating under transient conditions. Additionally it proves the linear relationship between the ZSVC and speed, which is effectively used as a fault severity index. The acquired ZSVC temporal signal is processed by means of the Hilbert-Huang transform (HHT). Experimental results presented in this work show the advantages of the method to provide helpful data for online diagnosis of stator winding inter-turn faults.
机译:该工作提出了定子三相电压的零序电压分量(ZSVC)作为用于检测绕组的绕组的方法,该方法在瞬态条件下操作的永磁同步电动机PMSM中的转弯短路。此外,它证明了ZSVC和速度之间的线性关系,其有效地用作故障严重性指数。通过Hilbert-Huang变换(HHT)处理所获得的ZSVC时间信号。本作工作中提出的实验结果表明了该方法的优点,以提供有用的数据在线诊断定子绕组匝间故障。