Conductivity detection can be considered electrochemical technique as well but has the ability to detect any analyte irrespective of whether it contains an electroactive species or not. We used MEMS to fabricate the microelectrode. The Micro-channel was made by PDMS and modified by O{sub}2 plasma. In this study we detected organic components such as catechol, dopamine, histamine and vitamin C, and inorganic ions like K{sup}+, Li{sup}+ and Ca{sup}(2+). In 30 sec electrokinetic injection time for individual sample detection was performed using a field strength (E) of 440 V/cm, and E = 230 V/cm for separation electrophoresis. Each sample can be detected less than 90 sec excluding catechol.
机译:电导率检测也可以被认为是电化学技术,但能够检测任何分析物,而不管它是否含有电活性物质。我们使用MEMS来制造微电极。微通道由PDMS制备并由O {Sub} 2等离子体进行修饰。在该研究中,我们检测了有机组分,例如儿茶酚,多巴胺,组胺和维生素C,以及类似K {sup} +,li {sup} +和ca {sup}(2+)的无机离子。在30秒的电动喷射中,使用440 v / cm的场强(e)进行各种样品检测,E = 230V / cm用于分离电泳进行。可以检测每个样品小于90秒,不包括儿茶酚。