Development of piezo-electric sensor based noninvasive low cost Arterial Pulse Analyzer

机译:基于压电传感器的无创低成本脉搏分析仪的开发

获取原文

摘要

Recent researches have demonstrated implications of Arterial Pulse analysis from Radial and Brachial artery on cardiovascular, renal and autonomic nervous system, as early indicator of major ailments. We have developed a low-cost Arterial Pulse Analyzer which provides run-time display of Arterial Pulse waveforms during the test as well as provides analysis of the waveforms in digitally storable format. The dynamic pressure waves at radial and brachial arteries are recorded non-invasively using piezoelectric ceramic plate sensors. The parameters analyzed are: S-P-T-C-D points, Augmentation index, pulse wave velocity, 2nd derivative analysis for arterial ageing index, Pulse rate variability and Power Spectrum of Pulse rate variability. The setup is portable and consists of 2 straps, one each for Radial and Brachial artery, with sensors mounted on them. Signal Processing and Analysis is done using Python on a Tablet PC. It is aimed to become a potential automatic cardiovascular screening device for public health centers in developing countries as they typically lack medical expertise and access to diagnostic devices for cardiovascular diseases. Commercially available arterial pulse analyzers are not portable and have an average cost of around 4000USD. This system is portable, requires minimal power and cost 100USD, several of the technologies employed being free or open-source.
机译:最近的研究表明Rad动脉和肱动脉的动脉搏动分析对心血管,肾脏和自主神经系统的影响,作为重大疾病的早期指标。我们已经开发了一种低成本的动脉脉搏分析仪,它可以在测试过程中实时显示动脉脉搏波形,并以数字可存储格式对波形进行分析。使用压电陶瓷板传感器无创地记录radial动脉和肱动脉的动态压力波。分析的参数为:S-P-T-C-D点,增强指数,脉搏波速度,动脉衰老指数的二阶导数分析,脉搏率变异性和脉搏率变异性的功率谱。该装置是便携式的,由2条皮带组成,每条皮带分别用于Rad动脉和肱动脉,并在其上安装传感器。信号处理和分析是在Tablet PC上使用Python完成的。它的目标是成为发展中国家公共卫生中心的潜在自动心血管检查设备,因为它们通常缺乏医学专业知识并且无法获得心血管疾病的诊断设备。市售的动脉脉搏分析仪不是便携式的,平均成本约为4000美元。该系统是便携式的,仅需最小的功率,成本为100美元,所采用的几种技术是免费的或开源的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号