This paper describes the basic theory and detection methods of UHF, ultrasonic and high-frequency on-site detection. With the example of failed switchgear on-site detection in 35kV substation, this paper analyzes the application of multi-sensor partial discharge detection technique in the area of switchgear insulation defects detection. Combined with the on-site analysis and disassembled maintenance, the paper verifies the switchgear detection and location's feasibility and accuracy of multi-sensors technique.
机译:本文介绍了UHF,超声波和高频现场检测的基本理论和检测方法。随着35kV变电站的故障开关设备现场检测的例子,本文分析了多传感器局部放电检测技术在开关设备绝缘缺陷检测区域中的应用。结合现场分析和拆卸维护,纸张验证了开关设备检测和位置的多传感器技术的可行性和准确性。