In inverter-based distributed generation (IBDG) and similar to the conventional third order LCL filter, the high order LLCL filter is difficult to stabilize, and may cause a resonance between the inverter and the grid. Passive damping techniques were explored in literature by connecting a resistor in different locations of the LLCL filter. This paper presents the performance of the high-order LLCL-filter with RC passive damping circuit through evaluating the system stability using dual-loop control strategy that has been applied to the LCL-filter. Comparative analysis regarding PI and PR controllers used in the proposed control strategy is offered. Simulation results using Matlab are conducted, presented, and discussed.
机译:在基于逆变器的分布式发电(IBDG)中并且类似于传统的三阶LCL滤波器,难以稳定高阶LLCL滤波器,并且可能导致逆变器和网格之间的共振。 通过在LLCL滤波器的不同位置连接电阻来探索被动阻尼技术。 本文通过使用已应用于LCL滤波器的双环控制策略评估系统稳定性,介绍了高阶LLCL-滤波器的性能。 提供了关于所提出的控制策略中使用的PI和PR控制器的比较分析。 进行,展示和讨论使用MATLAB的仿真结果。