首页> 外文会议>IET Renewable Power Generation Conference >Feasibility study of district heating with CHP, thermal store and Heat Pump
【24h】

Feasibility study of district heating with CHP, thermal store and Heat Pump

机译:CHP,热储存和热泵区采电的可行性研究

获取原文

摘要

Integration of Combined Heat and Power (CHP) plant, Heat Pump (HP), Thermal Storage (TS) and auxiliary boiler into a district heating scheme is able to provide an efficient way of using energy. This paper analyses the feasibility of such a scheme in Ebby Vale using the EnergyPro tool under existing energy market and policies. In the scenario based simulation, a 40279.7 MWh worth of heat was sent. The results show that the CHP+TS system present more encouraging environmental performance and acceptable profit margin, whilst the economic potential can be enhanced further with the addition of a HP unit. A sensitivity analysis was conducted to show to which extent economic assumptions will vary the result.
机译:结合热量和功率(CHP)植物,热泵(HP),热存储(TS)和辅助锅炉集成到区域加热方案中能够提供有效的使用能量方式。本文使用现有能源市场和政策下的EnergyPro工具分析了EBBY VALE在EBBY VALE的可行性。在基于场景的仿真中,发送了40279.7米的热量。结果表明,CHP + TS系统呈现出更令人鼓舞的环境性能和可接受的利润率,同时可以通过添加HP单位进一步加强经济潜力。进行了敏感性分析,表明经济假设将如何变化。