Radiation Protection on Patient Dosimetry

机译:患者剂量测定法的辐射保护

获取原文

摘要

The increase of population has led to an increase in the population of health care. X-rays are often used for diagnostic in the medical field. It is often used for a medical check-up in the thoracic area to identify any illnesses, such as calcification or spotting of any other type of illnesses. In this way, thermoluminescent dosimeter (TLD) chips were used to measure the radiation exposure to patients in order to identify the amount of radiation released during the examination in a hospital in South Jakarta. These data may be used as a reference to improve the radiation dosage, in order for the radiation dosage to be low as possible while optimizing the image as much as possible. The study was conducted using twelve patients and had a satisfying result with the optimization of the image while conducting with a low dosage of radiation. Therefore, the x-ray used at a hospital has been justified and were compatible with the International Atomic Energy Agency (IAEA) and Badan Pengawas Tenaga Nuklir (BAPETEN) regulations. The result of the data was also compared with previous studies and came up with a satisfying result.
机译:人口的增加导致了卫生保健人口增加。 X射线通常用于诊断医学领域。它通常用于胸腔区域的医学检查,以识别任何疾病,例如钙化或发现任何其他类型的疾病。通过这种方式,使用热辐发光剂量计(TLD)芯片来测量患者的辐射暴露,以确定在南雅加达医院检查期间释放的辐射量。这些数据可以用作改善放射剂量的参考,以便使辐射剂量尽可能低,同时尽可能地优化图像。使用12名患者进行该研究,并在用低剂量的辐射进行时,在图像的优化时进行了满意的结果。因此,在医院使用的X射线已经证明,与国际原子能机构(原子能机构)和巴丹鹏·塔加诺(Badanpengabas Tenaga Nuklir(Bapeten)法规兼容。还与先前的研究相比,数据的结果也与令人满意的结果进行了比较。