The structural features of the once-through boiler-turbine unit are nonlinear, strong coupling and multi-parameter, which affect the response ability of load of its coordinated control system. In order to improve the control performance of the once-through boiler-turbine coordinated system, a control method of feedforward-feedback control based on the nonlinear model of the once-through boiler-turbine unit was proposed in this article. First a nonlinear model that has certain accuracy and is fit for the controller design was established after reasonable reduce. Then the theory of stable inversion was introduced to seek the inversion solution of the nonlinear model. Feedforward control via inversion system leads the outputs of unit to the set points rapidly, while the feedback controller is designed for multivariable outputs to remove the tracking errors caused by external interference. Finally, simulation tests of the state disturbance and set point perturbation in different static operating conditions were carried out. Simulation results verify that the outputs of feedforward-feedback control method can track the set points accurately and fast.
机译:一致锅炉 - 涡轮机单元的结构特征是非线性,强耦合和多参数,影响其协调控制系统的负载的响应能力。为了提高一次通过锅炉 - 汽轮机协调系统的控制性能,本文提出了一种基于一致锅炉 - 涡轮机组的非线性模型的前馈 - 反馈控制的控制方法。首先,在合理的减少后建立了具有一定准确性并且适合控制器设计的非线性模型。然后引入了稳定反演理论以寻求非线性模型的反转溶液。通过反转系统的前馈控制将单元的输出快速引导到设定点,而反馈控制器专为多变量输出而设计,以消除由外部干扰引起的跟踪误差。最后,执行了不同静态操作条件下的状态干扰和设定点扰动的仿真试验。仿真结果验证了前馈 - 反馈控制方法的输出可以准确且快速跟踪设定点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号