首页> 外文会议>International Future Energy Electronics Conference >Loss comparison of Z-source inverter from the perspective of short-through mode implementation and type of switching device
【24h】

Loss comparison of Z-source inverter from the perspective of short-through mode implementation and type of switching device

机译:Z源逆变器损耗比较从短路模式实现和交换装置类型的角度

获取原文
获取外文期刊封面目录资料

摘要

This paper reports power losses of Z-source inverter due to switching device and short-through mode. The Z-source inverter has number of possibilities of short-through mode. This paper compares losses with 1-leg short-through, and 3-leg short-through modes. When SiC-MOSFETs are used as a switching devices, employing the 3-leg short-through mode is confirmed to be an advantage due to comparatively low switching losses. On the other hand, 1-leg short-through mode for Si-IGBTs is advantage due to comparatively low conduction losses. It is understood that optimization of switching pattern of short-through mode is required to archive high efficiency for Z-source inverter.
机译:本文报告了Z源逆变器电源损耗由于开关设备和短路模式。 Z源逆变器具有短​​路模式的可能性。本文将损耗与三腿短路和3腿短路模式进行比较。当SiC-MOSFET用作开关器件时,由于相对低的开关损耗,确认使用3腿短路模式是一个优点。另一方面,由于相对低的导电损耗,Si-IGBT的1腿短通模式是优势。据了解,需要优化短通模式的开关模式来归档Z源逆变器的高效率。