The maximum operation frequency of a permanent magnet electrodynamic shaker (PMEDS) is 2kHz. To provide good current tracking performance in digital implementation, the PWM frequency is chosen to be 100kHz. Due to the finite turning-on time and the turning-off time of the conventional semiconductor devices, the dead-time has a great effect on the current tracking performance and thus, the dead-time compensation loops need to be included to the current control loop. By using the high-speed high-efficiency GaN devices, the dead-time is near zero and no dead-time compensation loop is required, which simplifies the current control design and saves the calculating time of digital current loop. In addition, the results also show that the GaN devices contribute to less acceleration harmonics and less input power in the application of PMEDS.
机译:永磁电动振动筛(PMEDS)的最大工作频率为2kHz。为了在数字实现中提供良好的电流跟踪性能,将PWM频率选择为100kHz。由于常规半导体器件的导通时间和截止时间有限,因此空载时间对电流跟踪性能有很大影响,因此,空载时间补偿回路需要包含在电流控制中环形。通过使用高速高效GaN器件,空载时间接近于零,并且不需要空载时间补偿环路,从而简化了电流控制设计并节省了数字电流环路的计算时间。此外,结果还表明,在PMEDS的应用中,GaN器件对加速谐波和输入功率的贡献较小。