The electrical health of solar arrays is verified by different tests. Solar array electrical performance tests are grouped in two categories, either requiring accurate or comparative results. Accurate electrical performance is performed with LAPSS and comparative electrical performance can be performed also with Mini-flasher test equipments. Mini-flasher tests have provided very valuable data on the health of several ESA satellite solar arrays with single junction solar cells. With the advent of the triple-junction solar cells, the same test principle of the mini-flasher is applicable. This paper presents test set-up requirements and measurement reproducibility. Analysis of results of LAPSS and Mini-flasher solar array measurements are provided.
机译:通过不同的测试验证了太阳阵列的电气运行状况。太阳能阵列电气性能测试分为两类,无论是准确还是对比结果。用圈子进行准确的电气性能,也可以使用迷你闪光灯测试设备进行比较电气性能。迷你闪光灯测试提供了有关单个接合太阳能电池的几个ESA卫星太阳能阵列的健康状况非常有价值的数据。随着三界太阳能电池的出现,迷你闪光灯的相同测试原理是适用的。本文提出了测试设置要求和测量再现性。提供了圈和迷你闪光阵列测量结果的分析。