首页> 外文会议>European Photovoltaic Solar Energy Conference and Exhibition >PERFORMANCE ANALYSIS OF TWO TWINS GRID CONNECTED THIN FILM PV INSTALLATIONS 2.18KWP FOR THE FIRST TWO (2) YEARS OF THEIR OPERATION IN THE ISLAND OF CRETE AND IN ATHENS
【24h】

PERFORMANCE ANALYSIS OF TWO TWINS GRID CONNECTED THIN FILM PV INSTALLATIONS 2.18KWP FOR THE FIRST TWO (2) YEARS OF THEIR OPERATION IN THE ISLAND OF CRETE AND IN ATHENS

机译:在克里特岛和雅典的运营的后两(2)年内,两个双绞网连接薄膜光伏装置的性能分析2.18KWP

获取原文

摘要

This study presents the performance analysis of two twin grid connected PV Systems, installed in twohellenic areas: the Agricultural University of Athens (37o 59' N, 23o 42' E) and the Technical University of Crete,Chania (35o 31' N, 24o 04' E). Both installations consist of tandem amorphous and microcrystalline silicon thin film (a-Si/μ-Si ) solar modules (SHARP NA-F121G5). The nominal power output of each system at STC is 2.178 W. Theperformance analysis is drawn on data that have been collected during a two (2) years period (June 2010-May 2012).The aim of this paper is to present the performance analysis of the previous mentioned PV twin installations.Additionally comparisons are made between their performances and between the performance of each of them in thefirst and the second year of operation under high-temperature subtropical Mediterranean area conditions. To evaluatethe performance of each PV system some important normalized parameters such as yields, losses and efficiencies arecomputed. These parameters include the final yield (YF), the reference yield (YR), the array yield (YA), the performanceratio (PR) ,the PV array efficiency (n_(PV)), the system efficiency (n_(sys)), the inverter efficiency (n_(inv)) . The Array capturelosses (L_c) and System losses (L_s) were also calculated.
机译:本研究介绍了两个安装在两个中的双并网光伏系统的性能分析 希腊地区:雅典农业大学(北纬37o 59',东经23o 42')和克里特技术大学, 干尼亚(35o 31'N,24o 04'E)。两种装置均由串联非晶硅和微晶硅薄膜(a- Si /μ-Si)太阳能模块(SHARP NA-F121G5)。每个系统在STC时的标称功率输出为2.178W。 根据两(2)年(2010年6月至2012年5月)收集的数据进行性能分析。 本文的目的是介绍前面提到的光伏双胞胎装置的性能分析。 此外,还比较了它们的性能以及它们各自在性能中的性能。 在高温亚热带地中海地区条件下运营的第一年和第二年。评估 每个光伏系统的性能都有一些重要的标准化参数,例如产量,损耗和效率 计算的。这些参数包括最终产量(YF),参考产量(YR),阵列产量(YA),性能 比率(PR),PV阵列效率(n_(PV)),系统效率(n_(sys)),逆变器效率(n_(inv))。数组捕获 还计算了损耗(L_c)和系统损耗(L_s)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号