首页> 外文会议>International conference on gas discharges and their applications >ELECTRIFIED DROPLET ON CORONA-CHARGED SILICONE RUBBER NANOCOMPOSITE FOR HVDC OUTDOOR INSULATOR
【24h】

ELECTRIFIED DROPLET ON CORONA-CHARGED SILICONE RUBBER NANOCOMPOSITE FOR HVDC OUTDOOR INSULATOR

机译:HVDC户外绝缘子用电晕硅橡胶纳米复合材料上的电滴

获取原文

摘要

In HVDC transmission lines, corona could occur even on well designed hardware and insulators, which can significantly damage and inject the charge in the surface of insulators. Once a charged droplet deposited on the surface, the insulation performance of the insulators will be affected. In this research, the characteristic of an electrified droplet on corona-charged silicone rubber (SiR) nanocomposite surface was observed under dc voltage stress. The samples were made by dispersing nano-scale SiO2 powdered in SiR with the weight ratios of 0, 1, 2, 3 wt%, and were charged for 5 minutes under a dc corona discharge system based on needle-plate electrode. Then the flashover test was carried out under a dc stress between two aluminum plate electrodes. The effect of nanoparticles weight percent on the surface charge density and the surface charge on contact angle was obtained. The relationships among the charge density, the contact angle and the flashover voltage via the droplet were obtained. The results show that charged droplet deposited on charged surface has a negative effect on the insulation performance of insulators and nanoparticles filled in the SiR can make the flashover occur even at lower voltage.
机译:在高压直流输电线路中,即使在设计良好的硬件和绝缘子上也可能发生电晕,从而严重损坏绝缘子表面并注入电荷。一旦带电液滴沉积在表面上,绝缘子的绝缘性能将受到影响。在这项研究中,在直流电压应力下观察到了带电晕的硅橡胶(SiR)纳米复合材料表面带电液滴的特性。通过将粉末状的纳米级SiO2分散在SiR中以重量比为0、1、2、3 wt%的方式制备样品,并在基于针板电极的dc电晕放电系统下充电5分钟。然后在两个铝板电极之间的直流应力下进行闪络测试。获得了纳米颗粒重量百分数对表面电荷密度和表面电荷对接触角的影响。获得了通过液滴的电荷密度,接触角和闪络电压之间的关系。结果表明,沉积在带电表面上的带电液滴对绝缘子的绝缘性能有负面影响,而填充在SiR中的纳米颗粒甚至在较低电压下也会使闪络发生。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号