A Method for Estimating Frost Heave Forces Acting on Ground Anchors

机译:一种估计在地锚上作用的霜冻升降力的方法

获取原文

摘要

The ground anchor method for slope stability is widely used for cut slopes and walls as either a permanent or temporary stabilization of ground in cold regions. However, we have observed deformation of top steel plates, failure of concrete frames, and even pull out of wires due to over tensioning forces, all possibly caused by the frost heave of ground during low temperatures. We do not have an appropriate design method or code in Japan to take into account the frost heave force acting on ground anchor wires when the ground is supposed to be frost susceptible. In this paper, a design method is introduced to estimate the frost heave forces acting on ground anchors as a required additional force, using a well-used frost heave model, results of laboratory frost heave tests, and several assumptions on the elasticity of frozen ground. The estimated values are compared to the observed failure data at the ground-anchored slope, and the method is evaluated as a reasonable approach.
机译:用于坡度稳定性的地面锚定方法广泛用于切割斜面和墙壁,作为寒冷区域的永久或暂时稳定地。然而,我们观察到顶部钢板的变形,混凝土框架的失效,甚至由于过度张紧力而拔出导线,绝对可能由霜冻在低温期间接地引起的。我们在日本没有适当的设计方法或代码,以考虑当地面应该是霜冻的当地面时的冰霜升降力作用在地锚线上。在本文中,引入了一种设计方法来估计作为所需的额外力,使用过良好使用的霜冻模型,实验室霜冻测试的结果以及冻结地弹性的几个假设,估计在地锚上作用的霜冻升降力。 。将估计值与地面锚定斜率的观察失效数据进行比较,并且该方法被评估为合理的方法。