首页> 外文会议>Congress on forensic engineering >The Anatomy of the Failure of a Wood Panelized Roof Sub-Purlin Hanger
【24h】

The Anatomy of the Failure of a Wood Panelized Roof Sub-Purlin Hanger

机译:木板化屋顶底缘吊架失效的解剖

获取原文

摘要

Sagging roof surfaces and broken sub-purlins can be the result of construction defects to wood panelized roof systems; however, roofs with no signs of failure or distress may still be degraded to the point of detachment and failure. Although a detachment of an individual purlin may not result in the collapse of the roof or even a portion of the roof, it may represent a potential life safety hazard to the occupants of the building. This paper will discuss the design, construction, and failure of a sub-purlin hanger at a large warehouse that resulted in the investigation and remediation of over (370,000 square meters) 4 million square feet of warehouse roofs. This paper will present the viewpoint of an investigator working for the building owner/developer (WJE) and the viewpoint of an investigator working for the roof framing subcontractor's insurance company (DC). The factors involved during the original design and construction will be discussed as well as the methods used to determine the adequacy of the remaining sub-purlin hangers. Although the paper does not offer a formula for identifying hidden failures, it demonstrates that a process can be implemented to reduce future sub-purlin hanger failures to an acceptable level.
机译:下垂的屋顶表面和破碎的亚木质可以是木镶板屋顶系统的施工缺陷的结果;然而,没有失败迹象或痛苦迹象的屋顶可能仍然可以降低分离点和失败。虽然单独的PURLIN的分离可能不会导致屋顶的塌陷甚至屋顶的一部分,但它可能代表到建筑物的乘员的潜在生命安全危险。本文将讨论一个大型仓库的设计,施工和失效,导致对(370,000平方米)400万平方英尺的仓库屋顶进行调查和修复。本文将介绍为建筑所有者/开发人员(WJE)工作的调查员的观点以及为屋顶框架分包商保险公司(DC)工作的调查员的观点。将讨论在原始设计和施工期间涉及的因素以及用于确定剩余的亚紫曲线衣架的充分性的方法。虽然论文没有提供用于识别隐藏失败的公式,但它表明可以实现一个过程以将未来的子假衣架失败降至可接受的水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号