首页> 外文会议>Corrosion conference and expo;Corrosion 2012 >Evaluation of FBE Coatings for High Temperature Pipeline Applications
【24h】

Evaluation of FBE Coatings for High Temperature Pipeline Applications

机译:高温管道应用的FBE涂层评估

获取原文
获取外文期刊封面目录资料

摘要

In oilfields from Colombia, the surface operating temperatures of pipelines are around 120°C. Actually, Canadian and ASTM standard tests set the conditions for Cathodic Disbonding Testing to maximum temperature of 95 °C, while our scope for coating evaluation is between 95 to 150 °C. To select for higher performance coatings systems, we have developed a testing protocol to be applied at the factory, in the laboratory and in the field to assess the performance of coatings for operating conditions between 95 to 150°C. The protocol involved the following tests: dry film thickness, porosity, mechanical, abrasion resistance test, impact and elongation, adhesion, wet adhesion, immersion in chemical solution, cathodic disbonding and electrochemical impedance. The results in the laboratory can be correlated between the glass transition temperature and the electrochemical response. To clarify damage level found in the coatings evaluated. As a result of this work was found a reliable methodology for evaluating coatings at temperatures above 95°C. A good correlation was found in the results of electrochemical impedance tests and cathodic disbondment evaluated to 150°C.
机译:在哥伦比亚的油田中,管道的地面操作温度约为120°C。实际上,加拿大和ASTM标准测试将阴极剥离测试的条件设置为最高温度为95°C,而我们的涂层评估范围为95至150°C。为了选择性能更高的涂料系统,我们开发了一种测试协议,可在工厂,实验室和现场应用,以评估在95至150°C的工作条件下涂料的性能。该协议包括以下测试:干膜厚度,孔隙率,机械性能,耐磨性测试,冲击和伸长率,附着力,湿附着力,浸入化学溶液中,阴极剥离和电化学阻抗。实验室中的结果可以在玻璃化转变温度和电化学响应之间建立关联。为了弄清评估涂层中的损坏程度。这项工作的结果是发现了一种可靠的方法,可用于评估高于95°C的温度下的涂层。在电化学阻抗测试结果和评估至150°C的阴极剥离性能中发现了良好的相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号