Some recent papers contain inaccurate information regarding the validity of the -850 mV_(CSE) current applied criterion, the so-called on-potential criterion. To qualify as a corrosion control criterion the -850mV_(CSE) value must imply a sound engineering judgment of the corrosion rate. Only the -850 mV_(CSE) polarized potential criterion does this, as supported theoretically and empirically through its development, where a corrosion rate of less than 1mpy (< 0.025mm/a) is generally accepted. There is no similar scientific backing for the -850 mV_(CSE) on-potential criterion. Numerous comparative studies of these two criteria illustrate that the corrosion rate can not be judged on the basis of an on-potential criterion when the IR drop is ignored. Failure to correct the on-potential measurement, by removing the IR drop, leaves the public exposed to an unnecessary safety risk.
机译:最近的一些论文包含有关-850 mV_(CSE)当前应用标准(即所谓的接通电势标准)的有效性的不准确信息。为了符合腐蚀控制标准,-850mV_(CSE)值必须暗示对腐蚀速率的合理工程判断。在理论上和经验上都支持-850 mV_(CSE)极化电位准则,因此其腐蚀速率低于1mpy(<0.025mm / a)通常是可接受的。 -850 mV_(CSE)的电势准则没有类似的科学依据。对这两个标准的大量比较研究表明,当忽略IR下降时,不能根据准电位标准来判断腐蚀速率。通过消除红外压降无法校正电势测量值,会使公众面临不必要的安全风险。