Capacitive ECG sensing is not just a very promising alternative to conventional ECG but also allows for new applications, in which recording a conventional ECG is not imaginable due to practical aspects. This way, integration into car seats for monitoring of the heart rate of the driver or a usage in a home monitoring scenario is no longer unimaginable. Nevertheless, capacitive ECG measurements are very prone to motion artifacts, which need to be eliminated. For this purpose, this paper introduces adaptive filtering as a method for signal enhancement by using a second signal, which is correlated with the interfering signal. The approach is validated in a setting with an additional acceleration signal during car drive.
机译:电容式ECG感应不仅是传统ECG的非常有前途的替代方案,而且还允许进行新的应用,在这些应用中,由于实际情况,无法想象记录传统ECG。这样,不再难以想象将其集成到汽车座椅中以监视驾驶员的心率或在家庭监视中的用途。然而,电容式ECG测量非常容易产生运动伪影,需要消除这些伪影。为此,本文引入自适应滤波作为一种通过使用与干扰信号相关的第二信号来增强信号的方法。该方法在汽车驾驶过程中通过附加加速度信号的设置中得到了验证。