Time Series of Cross-calibration of HJ-1B Thermal Infrared Channel

机译:HJ-1B热红外通道交叉校准的时间序列

获取原文

摘要

The absolute calibration of HJ-1B thermal infrared channel is achieved by 7 times cross-calibration of Qinghai Lake in 2010, between the HJ-1B thermal infrared channel and MODIS 31, 32 channels. At the same time, the intercept of calibration coefficients is calculated. First, the spatial match are completed between the HJ-1B IRS image and MODIS 31, 32 channels image. Then, the spectral response of HJ-1B IRS thermal channel and MODIS 31, 32 channels are used for the spectral match. Based on the SST algorithms of MODIS, the MODTRAN4.0 is used to simulate the radiative transfer results under the condition of variety surface temperature of the Qinghai Lake, the atmospheric profile, observational geometry combined with the spectral response functions of the remote sensors. The quantitative linear relationship can be established with the simulation results. The gain and offset of cross-calibration are 52.7788 1/(W/(m2·sr·μm)), -55.4137. The result needs further validation of longer sequence.
机译:HJ-1B热红外通道的绝对校准是通过2010年青海湖在HJ-1B热红外通道和MODIS 31、32通道之间进行7次交叉校准而实现的。同时,计算校准系数的截距。首先,在HJ-1B IRS图像和MODIS 31、32通道图像之间完成空间匹配。然后,将HJ-1B IRS热通道和MODIS 31、32个通道的光谱响应用于光谱匹配。基于MODIS的SST算法,利用MODTRAN4.0软件模拟了青海湖表面温度变化,大气廓线,观测几何以及遥感器的光谱响应函数等条件下的辐射传输结果。可以通过仿真结果建立定量线性关系。交叉校准的增益和偏移为52.7788 1 /(W /(m2·sr·μm)),-55.4137。结果需要进一步验证更长的序列。