Based on the analysis of the drive circuit for both mono-stable and bi-stable vacuum circuit breaker (VCB), a controller can control both of them was designed in this paper. A new method was introduced to determine the actual state of the VCB that had just executed the switching command. The method divided the curve of the drive current into three periods, and analyzed the state of the moving contact. An algorithm was implemented, which was used to detect the similarity between the idea drive current and the actual one acquired by the controller, to determine the state of contacts in VCB. Experiments were made on VCB, and it was found out that the reliability of closing the VCB could be improved with the method.
机译:在对单稳态和双稳态真空断路器(VCB)的驱动电路进行分析的基础上,设计了一种可同时控制两者的控制器。引入了一种新方法来确定刚刚执行了切换命令的VCB的实际状态。该方法将驱动电流的曲线分为三个周期,并分析了动触头的状态。实现了一种算法,该算法用于检测想法驱动电流与控制器获取的实际驱动电流之间的相似性,以确定VCB中的触点状态。对VCB进行了实验,发现该方法可以提高关闭VCB的可靠性。