Condensate pump is employed to pump the water in condenser to deaerator, maintains the water height in deaerator and enables units operate continuously. Currently, system efficiency of 600 MW units is comparatively low due to high design pressure head and large throttling pressure loss. This paper takes NLT500-570x4S condensate pump as example, and analyzes its existing problems based on performances test. Further, aims at solve these problems, some modification works, such as reducing the throttling pressure loss and reforming the through-flow as well as improving the craft of inspection, are performed. The results show that the highest efficiency of the condensate pump was improved with 5.5% under the best design flux.
机译:冷凝水泵用于将冷凝器中的水泵送到除氧器,维持除氧器中的水位,并使机组连续运行。当前,由于高设计压头和大节流压力损失,600 MW机组的系统效率相对较低。本文以NLT500-570x4S凝结水泵为例,并通过性能测试分析其存在的问题。此外,为了解决这些问题,进行了一些改进工作,例如减少节流压力损失和重整通流以及改进检查技术。结果表明,在最佳设计流量下,凝结水泵的最高效率提高了5.5%。