首页> 外文会议>International symposium on fiber-reinforced polymer reinforcement for concrete structures >TESTS AT HIGH TEMPERATURES ON CONCRETE SLABS REINFORCED WITH BENT FRP BARS
【24h】

TESTS AT HIGH TEMPERATURES ON CONCRETE SLABS REINFORCED WITH BENT FRP BARS

机译:弯曲FRP筋加固的混凝土板在高温下的测试

获取原文

摘要

Three fire tests were carried out on slabs reinforced with Glass Fiber Reinforced Polymer (GFRP) bars bent at the ends of the member and the results were compared to those of six tests conducted previously. The anchoring of the FRP bars in the zone of slab not directly exposed to fire at the end of the members, provided by bending the bar ends, revealed essential to ensures slab resistance once in the fire exposed zone of slab the glass transition temperature was attained and the resin softening reduced the adhesion at the FRP-concrete interface. Therefore similar good performances of some of the six concrete slabs previously tested were later obtained even if a shorter length of the anchoring zone not directly exposed to fire was adopted. The production process allowing the bar to be bent is easily implemented by FRP bars manufacturers owing technologically advanced systems.
机译:在用弯曲在构件端部的玻璃纤维增​​强聚合物(GFRP)筋增强的平板上进行了三个防火测试,并将结果与​​之前进行的六个测试进行了比较。将FRP筋固定在不直接暴露在构件末端的火中的平板区域中(通过弯曲钢筋端部),这对于确保在平板的火暴露区域中达到玻璃化转变温度后的耐平板性至关重要。树脂软化会降低FRP-混凝土界面的粘合力。因此,即使采用较短长度的不直接暴露于火中的锚固区域,后来也获得了先前测试的六块混凝土板中类似的良好性能。 FRP钢筋制造商由于采用了先进的技术系统,因此可以轻松弯曲钢筋的生产过程。